Search results for " nct"

showing 8 items of 8 documents

Fricke gel, electron spin resonance and thermoluminescence for integration and intercomparison of measurements in NCT dosimetry

2014

Fricke gel ESR dosimetry Alanine NCT TLDSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

I fenoli come nuovi materiali per la dosimetria EPR in campo misto neutroni-gamma

2014

Settore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dosimetria EPR NCT Gadolinio neutroni fading
researchProduct

Determinazione della componente gamma nella colone termica del reattore TRIGA di Pavia tramite Dosimetri ESR di alanina

2016

Negli ultimi anni il crescente interesse verso la radioterapia a cattura neutronica (internazionalmente nota come Neutron Capture Therapy - NCT) per il trattamento di neoplasie ha stimolato diverse attività di ricerca finalizzate alla caratterizzazione del fascio utilizzato e all'ottimizzazione delle procedure radioterapiche. Tra i vari sistemi dosimetrici trovano largo impiego i rivelatori a stato solido ESR (Risonanza di Spin Elettronico) a base di alanina che presentano diversi vantaggi come la tessuto equivalenza, la linearità della risposta in un ampio intervallo di dose, l'elevata stabilità dei radicali liberi radioindotti, la non distruttività della lettura del dosimetro e il basso c…

campo misto neutroni gamma esr epr grafite nct neoplaisieSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Phenol compounds for Electron Spin Resonance (ESR) dosimetry in gamma and neutron field

2015

The use of neutrons for cancer treatments has stimulated the research for beam characterization in order to optimize the therapy procedures in Neutron Capture Therapy (Altieri, 2008). Several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. In particular, ESR spectrometry provides absorbed dose measurements through the detection of the stable free radicals produced by ionizing radiations. The ESR dosimetric method has many advantages such as simple and rapid dose evaluation, the readout procedure is non-destructive, linear response of many organic a…

ESR Gadolinium NCT PhenolsSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

CONVENTIONAL INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP FOR SMALL-TO-MEDIUM IDIOPATHIC MACULAR HOLE

2022

Purpose: To compare conventional internal limiting membrane (ILM) peeling versus inverted flap technique in small-to-medium idiopathic macular hole. Methods: Eyes with ≤400 μ m idiopathic macular holes were randomized into the conventional ILM peeling group (25 eyes) and inverted flap group (25 eyes). A 12-month follow-up was considered. Macular sensitivity (MS) change detected with MP-1 microperimetry was the primary outcome. Secondary outcomes included best-corrected visual acuity change, closure rate, anatomical findings on optical coherence tomography such as U-shape foveal contour, restoration of external limiting membrane, and ellipsoid zone. Results: In both groups, MS improved throu…

OphthalmologyVitrectomyClinicalTrials.gov NCT04498624.HumansEpiretinal MembraneGeneral MedicineRetinal PerforationsBasement MembraneTomography Optical CoherenceRetrospective StudiesRetina
researchProduct

Dosimetry of Mainz reactors by means of ESR dosimetry with alanine added with gadolinium

2014

Settore ING-IND/20 - Misure E Strumentazione NucleariESR dosimetry Alanine Gadolinium NCTSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

EPR ANALYSIS OF ALANINE WITH GADOLINIUM FOR DOSIMETRY AT TRIGA MARK II REACTOR OF MAINZ

2015

Negli ultimi anni il crescente interesse verso la radioterapia a cattura neutronica (internazionalmente nota come Neutron Capture Therapy - NCT) per il trattamento di neoplasie ha stimolato diverse attività di ricerca finalizzate alla caratterizzazione del fascio utilizzato e all'ottimizzazione delle procedure radioterapiche. La corretta riuscita del trattamento NCT e il monitoraggio della dose impartita non possono prescindere dalla valutazione delle varie componenti del fascio impiegato (neutronica e fotonica). Infatti, durante le procedure di moderazione dei neutroni, si verifica la produzione di fotoni e la stima dei rischi a cui sono soggetti i tessuti sani sottoposti al campo misto ne…

Settore ING-IND/20 - Misure E Strumentazione NucleariSettore ING-IND/18 - Fisica Dei Reattori NucleariSettore FIS/01 - Fisica SperimentaleMAINZ REACTOR DOSIMETRY ALANINE ESR EPR FLUKA NCT GADOLINIUMSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Neutron Electron Spin Resonance dosimetry with phenol compounds

2014

ESR EPR Dosimetry NCT PhenolsSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct